Part Number Hot Search : 
AD2210 1002C 12400 Q67006 UVC14ZLN AWS5506 16S45 TC323
Product Description
Full Text Search
 

To Download MB81EDS256445 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 MB81EDS256445
6. Address Inputs (A0 to A11)
Address input selects an arbitrary location of a total of 1,048,576 words of each memory cell matrix. Total twenty address input signals are required to decode such a matrix. Row Address (RA) is input from A0 to A11 and Column Address (CA) is input from A0 to A7. Row addresses are latched with ACTIVE (ACT or MACT) commands, and Column addresses and Auto Precharge (AP) bit are latched with Read (READ or READA) or Write command (WRIT or WRITA). * Command and address inputs setup and hold time
CK
tIS
Command (CS, RAS, CAS, WE) Address
tIH
tIPW
7. Input Data Mask (DM0 to DM7)
DM is an input mask signal for write data. Input data is masked when DM is sampled High on the both edges of DQS along with input data. DM0, DM1, DM2, DM3, DM4, DM5, DM6 and DM7 correspond to DQ[7:0], DQ[15:8], DQ[23:16], DQ[31:24], DQ[39:32], DQ[47:40], DQ[55:48] and DQ[63:56] respectively. Refer to the "DQ/DQS/DM Correspondence Table".
8. Data Bus Input / Output (DQ0 to DQ63)
DQ is data bus input / output signal.
9. Data Strobe (DQS0 to DQS7)
DQS is edge aligned with output read data and center aligned with input write data. DQS0, DQS1, DQS2, DQS3, DQS4, DQS5, DQS6 and DQS7 correspond to DQ[7:0], DQ[15:8], DQ[23:16], DQ[31:24], DQ[39:32], DQ[47:40], DQ[55:48] and DQ[63:56] respectively. Refer to the "DQ/DQS/DM Correspondence Table". * DQ/DQS/DM Correspondence Table DQ DQ[7:0] DQ[15:8] DQ[23:16] DQ[31:24] DQ[39:32] DQ[47:40] DQ[55:48] DQ[63:56] 4
DQS DQS0 DQS1 DQS2 DQS3 DQS4 DQS5 DQS6 DQS7
DM DM0 DM1 DM2 DM3 DM4 DM5 DM6 DM7 DS05-11456-1E
MB81EDS256445
BLOCK DIAGRAM
CK CK CKE CLOCK BUFFER
To each block
VDDQ VDD VSS VSSQ
A[11:0] ADDRESS BUFFER
BURST COUNTROLLER
Y CONTROLLER Bank3 Bank2 Bank1 Bank0 X CONTROLLER MEMORY CELL ARRAY (1 M bit x 64)
BA[1:0]
ADDRESS COUNTROLLER
CS RAS CAS WE COMMAND DECODER
MODE REGISTER
MEMORY CORE CONTROLLER
READ AMP
WRITE AMP
DM[7:0]
DQS[7:0]
I/O BUFFER
BUS CONTROLLER
DQ[63:0]
DS05-11456-1E
5
MB81EDS256445
SIMPLIFIED STATE DIAGRAM
SELF REFRESH SELF DEEP POWER DOWN DPD MRS PDX MODE REGISTER SET ACT
POWER DOWN
SELFX REF IDLE PD
AUTO REFRESH
BANK ACTIVE BST WRIT DPDX WRIT WRITE WRITA WRITA PRE READA
PD PDX BST READ READ
ACTIVE POWER DOWN
READ
READA
WRITE WITH AUTO PRECHARGE
PRE
PRE
READ WITH AUTO PRECHARGE
POWER ON
PRE
PRECHARGE
Automatic Sequence POWER APPLIED Manual Input
Note: "SIMPLIFIED STATE DIAGRAM" is based on the single bank operation. State transition of multi bank operation are not described in all detail.
6
DS05-11456-1E
MB81EDS256445
FUNCTIONAL DESCRIPTION
1. Power Up Initialization
This device internal condition after power-up will be undefined. The following Power up initialization sequence must be performed to start proper device operation. 1. 2. 3. 4. 5. 6. Apply power (VDD should be applied before or in parallel with VDDQ) and start clock. Attempt to maintain either NOP or DESL command at the input. Maintain stable power, stable clock, and NOP or DESL condition for a minimum of 300 s. Precharge all banks by PRECHARGE (PRE) or PRECHARGE ALL (PALL) command. Assert minimum of 2 AUTO REFRESH (REF) commands. Program the Mode Register by MODE REGISTER SET (MRS) command. Program the Extended Mode Register by MODE REGISTER SET (MRS) command.
In addition, CKE must be High to ensure that output is High-Z state. The Mode Register and Extended Mode Register can be set before 2 Auto-refresh commands (REF).
2. Mode Register
The Mode Register is used to configure the type of device function among optional features. This device has 2 Mode Registers, Mode Register and Extended Mode Register. Mode Registers can be programmed by MODE REGISER SET (MRS) command. Refer to the "Mode Register Table" in "FUNCTIONAL DESCRIPTION".
DS05-11456-1E
7
MB81EDS256445
3. Burst Length (BL)
Burst Length (BL) is the number of word to be read or write as the result of a single READ or WRITE command. It can be set on 2, 4, 8, 16 words boundary through Mode Register. The burst type is sequential that is incremental decoding scheme within a boundary address to be determined by burst length. Device internal address counter assigns +1 to the previous address until reaching the end of boundary address and then wrap round to least significant address ( = 0). Starting Column Address Burst Burst Address Sequence Length (Hexadecimal) A3 A2 A1 A0 2 X X X 4 X X X X X X 8 X X X X X 0 0 0 0 0 0 0 16 0 1 1 1 1 1 1 1 1 X X X X X X 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 X X 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0-1 1-0 0-1-2-3 1-2-3-0 2-3-0-1 3-0-1-2 0-1-2-3-4-5-6-7 1-2-3-4-5-6-7-0 2-3-4-5-6-7-0-1 3-4-5-6-7-0-1-2 4-5-6-7-0-1-2-3 5-6-7-0-1-2-3-4 6-7-0-1-2-3-4-5 7-0-1-2-3-4-5-6 0-1-2-3-4-5-6-7-8-9-A-B-C-D-E-F 1-2-3-4-5-6-7-8-9-A-B-C-D-E-F-0 2-3-4-5-6-7-8-9-A-B-C-D-E-F-0-1 3-4-5-6-7-8-9-A-B-C-D-E-F-0-1-2 4-5-6-7-8-9-A-B-C-D-E-F-0-1-2-3 5-6-7-8-9-A-B-C-D-E-F-0-1-2-3-4 6-7-8-9-A-B-C-D-E-F-0-1-2-3-4-5 7-8-9-A-B-C-D-E-F-0-1-2-3-4-5-6 8-9-A-B-C-D-E-F-0-1-2-3-4-5-6-7 9-A-B-C-D-E-F-0-1-2-3-4-5-6-7-8 A-B-C-D-E-F-0-1-2-3-4-5-6-7-8-9 B-C-D-E-F-0-1-2-3-4-5-6-7-8-9-A C-D-E-F-0-1-2-3-4-5-6-7-8-9-A-B D-E-F-0-1-2-3-4-5-6-7-8-9-A-B-C E-F-0-1-2-3-4-5-6-7-8-9-A-B-C-D F-0-1-2-3-4-5-6-7-8-9-A-B-C-D-E
DS05-11456-1E
9
MB81EDS256445
4. CAS Latency (CL)
CAS Latency (CL) is the delay between READ command being registered and first read data becoming available during read operation. First read data will be valid after (CL-1) x tCK + tAC from the CK rising edge where Read command being latched.
5. Driver Strength (DS)
Driver Strength (DS) is to adjust the driver strength of data output.
6. Pre Driver Strength (PDS)
Pre Driver Strength (PDS) is to adjust the transition time of the data output without changing the output driver impedance.
10
DS05-11456-1E
MB81EDS256445
COMMAND TRUTH TABLE
1) Basic Command Truth Table Command DESELECT *1 NO OPERATION *1 BURST TERMINATE * * READ * *
3, 4 2, 3
Symbol
CS H L L L L L L L L L L L
RAS X H H H H H H L L L L L
CAS X H H L L L L H H H L L
WE X H L H H L L H L L H L
BA X X X V V V V V V X X V
A10 (AP) X X X L H L H
A[9:0], A11 X X X CA CA CA CA RA
DESL NOP BST READ READA WRIT
3, 4
READ with Auto-precharge *3, *4 WRITE * *
3, 4
WRITE with Auto-precharge * * BANK ACTIVE *4, *5
WRITA ACT
PRECHARGE SINGLE BANK * * PRECHARGE ALL BANKS * * AUTO REFRESH *6 MODE REGISTER SET *7
5, 6
5, 6
PRE PALL REF MRS
L H X V
X X X V
Note: V = Valid, L = VIL, H = VIH, X can be either VIL or VIH, RA = Row Address, CA = Column Address All commands are assumed to be valid state transitions and latched on the rising edge of CK. CKE assume to be kept High. *1: NOP and DESL commands have the same functionality. Unless specifically noted, NOP will represent both NOP and DESL command in later description. *2: When the current state is IDLE and CKE=L, BST command will represent DPD command. Refer to the "CKE COMMAND TRUTH TABLE". *3: BST command can be applied to READ or WRIT. READA and WRITA must not be terminated by BST command. *4: READ, READA, WRIT and WRITA commands can be issued after the corresponding bank has been activated. Refer to the "SIMPLIFIED STATE DIAGRAM". *5: ACT command can be issued after corresponding bank has been precharged by PRE or PALL command. Refer to the " SIMPLIFIED STATE DIAGRAM". *6: REF command can be issued after all banks have been precharged by PRE or PALL command. Refer to the "SIMPLIFIED STATE DIAGRAM". *7: MRS command can be issued after all banks have been precharged and all DQ are in High-Z. Mode Register and Extended Mode Register are selected through BA input. Mode Register and Extended Mode Register must be set by MRS command after power up.
DS05-11456-1E
11
MB81EDS256445
2) CKE Command Truth Table Command
Symbol
CKE n-1 H n L
CS
RAS CAS
WE
BA
A[11:0]
SELF REFRESH ENTRY *1
SELF
L L
L H X H X H X H H X
L H X H X H X H H X
H H X H X H X L H X
X X X X X X X X X X
X X X X X X X X X X
SELF REFRESH EXIT *2
SELFX
L
H H L
POWER DOWN ENTRY *1
PD
H
L H L
POWER DOWN EXIT
PDX
L
H H
DEEP POWER DOWN ENTRY *1
DPD
H
L
L L
DEEP POWER DOWN EXIT
DPDX
L
H H
Note: V = Valid, L = VIL, H = VIH, X can be either VIL or VIH *1: SELF and DPD commands can be issued after all banks have been precharged and all DQ are in High-Z. *2: CKE should be held High more than tREFC period after SELFX.
12
DS05-11456-1E
MB81EDS256445
3) Single Bank Operation Current State CS RAS CAS WE IDLE H L L L L L L L L BANK ACTIVE H L L L L L L L L X H H H H L L L L X H H H H L L L L X H H L L H H L L X H H L L H H L L X H L H L H L H L X H L H L H L H L
Address X X X BA, CA, AP BA, CA, AP BA, RA BA, AP X MODE X X X BA, CA, AP BA, CA, AP BA, RA BA, AP X MODE
Command DESL NOP BST READ/READA WRIT/WRITA ACT PRE/PALL REF MRS DESL NOP BST READ/READA WRIT/WRITA ACT PRE/PALL REF MRS NOP Illegal *1 NOP
Function
Bank Active NOP *2 Auto Refresh *3 Mode Register Set *3, *4
Start Read; Determine AP Start Write; Determine AP Illegal *1 Precharge; Determine Precharge Type Illegal (Continued)
DS05-11456-1E
13
MB81EDS256445
Current State READ
CS H L L L L L L L L
RAS CAS WE X H H H H L L L L X H H H H L L L L X H H L L H H L L X H H L L H H L L X H L H L H L H L X H L H L H L H L
Address X X X BA, CA, AP BA, CA, AP BA, RA BA, AP X MODE X X X BA, CA, AP BA, CA, AP BA, RA BA, AP X MODE
Command DESL NOP BST READ/READA WRIT/WRITA ACT PRE/PALL REF MRS DESL NOP BST READ/READA WRIT/WRITA ACT PRE/PALL REF MRS NOP
Function
Burst Terminate BANK ACTIVE Interrupt burst read by new burst read; Determine AP Illegal Illegal *1 Terminate burst read by precharge IDLE Illegal NOP Burst terminate BANK ACTIVE Interrupt burst write by new burst read; Determine AP *5 Interrupt burst write by new burst write; Determine AP Illegal *1 Illegal (Continued)
WRITE
H L L L L L L L L
14
DS05-11456-1E
MB81EDS256445
Current State READ WITH AUTO PRECHARGE
CS H L L L L L L L L
RAS CAS WE X H H H H L L L L X H H H H L L L L X H H L L H H L L X H H L L H H L L X H L H L H L H L X H L H L H L H L
Address X X X BA, CA, AP BA, CA, AP BA, RA BA, AP X MODE X X X BA, CA, AP BA, CA, AP BA, RA BA, AP X MODE
Command DESL NOP BST READ/READA WRIT/WRITA ACT PRE/PALL REF MRS DESL NOP BST READ/READA WRIT/WRITA ACT PRE/PALL REF MRS Illegal Illegal *1 Illegal NOP Illegal Illegal *1 NOP Illegal
Function
WRITE WITH AUTO PRECHARGE
H L L L L L L L L
(Continued)
DS05-11456-1E
15
MB81EDS256445
Current State Write Recovering
CS H L L L L L L L L
RAS CAS WE X H H H H L L L L X H H H H L L L L X H H L L H H L L X H H L L H H L L X H L H L H L H L X H L H L H L H L
Address X X X BA, CA, AP BA, CA, AP BA, RA BA, AP X MODE X X X BA, CA, AP BA, CA, AP BA, RA BA, AP X MODE
Command DESL NOP BST READ/READA WRIT/WRITA ACT PRE/PALL REF MRS DESL NOP BST READ/READA WRIT/WRITA ACT PRE/PALL REF MRS NOP *2 Illegal Illegal *1 Illegal NOP
Function
Start Write; Determine AP Illegal *1 Illegal NOP Illegal
Precharging
H L L L L L L L L
(Continued)
16
DS05-11456-1E
MB81EDS256445
BANK OPERATION COMMAND TABLE
Minimum clock latency or delay time for single bank operation
2nd Command (same bank) READA WRITA READ PALL SELF
tMRD
*1, *2
WRIT
MRS
ACT
PRE
BST
MRS ACT READ READA WRIT 1st Command WRITA READ BST WRIT BST PRE PALL REF SELFX " - " : illegal
tMRD
tMRD

tMRD
tMRD
tMRD
tMRD
tRCD
*4
tRCD
tRCD
*6
*5
tRCD
*6
tRAS
tRAS
*1, *2
BL/2 + tRP BL/2 +1 + tDAL
1
1
BL/2 +CL
BL/2 +CL
1
*3
*3
1 BL/2 + tRP
*3
1 BL/2 + tRP
*3
BL/2 + tRP
*1, *2
*6
*6
BL/2 + tRP
BL/2 + tRP
*1
REF

*1
BL/2 + tRP
*1, *2
2 + tWTR
2 + tWTR
1
1
1 BL/2 +1 + tDAL
BL/2 +1 + tWR BL/2 +1 + tDAL
*3
BL/2 +1 + tWR BL/2 +1 + tDAL
*3
BL/2 +1 + tDAL
BL/2 +1 + tDAL
BL/2 +1 + tDAL
1 1 + tWTR
1 1 + tWTR
CL
CL 1
1
*3
1
*3
1
1
1 + tWR tRP 1
1 + tWR 1
*1, *2
tRP
tRP
*1
*1, *2
tRP
tRP
*2
tRP
tRP

tRP
1
1
tRP
*2
tRP
tREFC
tREFC

tREFC
tREFC
tREFC
tREFC
tREFC
tREFC
tREFC

tREFC
tREFC
tREFC
tREFC
tREFC
*1: Assume all banks are in IDLE state. *2: Assume output is in High-Z state. *3: Assume tRAS (Min.) is satisfied. *4: ACT to READA interval must be longer than tRAS - BL/2. *5: ACT to WRITA interval must be longer than tRAS - (1 + BL/2 + tWR). *6: Assume appropriate DM masking.
18
DS05-11456-1E
MB81EDS256445
Minimum clock latency or delay time for multi bank operation 2nd Command (other bank) READA WRITA READ PALL WRIT SELF
tMRD
*1
MRS
ACT
PRE
BST
MRS ACT READ READA WRIT 1st Command WRITA READ BST WRIT BST PRE PALL REF SELFX " - " : illegal
tMRD
tMRD

tMRD
tMRD
tMRD
tMRD
tRRD
1
1
1
*5
1
*5
1
1
tRAS
*1, *2
*1, *3
1
1
1
BL/2 +CL
*5
BL/2 +CL
*5
1
1
*4
1
*4
BL/2 + tRP
*1
*1, *3
1
BL/2
*5
BL/2
*5
BL/2 +CL 1
BL/2 +CL 1
BL/2 + tRP
1
BL/2 + tRP
*4
BL/2 + tRP
*1
REF

*1
BL/2 + tRP
*1
*1, *3
1
2 + tWTR
*5
2 + tWTR
*5
1 BL/2 +1 + tDAL
1
BL/2 +1 + tWR
*4
BL/2 +1 + tDAL
*1, *3
1
BL/2 +1 + tWTR 1
BL/2 +1 + tWTR 1 1 + tWTR 1
BL/2
BL/2
1
BL/2 +1 + tDAL
*4
BL/2 +1 + tDAL
BL/2 +1 + tDAL
CL
CL 1
1
1
*4
*1, *3
1 1 + tWTR
*1, *3
1
1
1
1 + tWR 1
*1, *2
tRP
1
1
1
1
1
1
*1
*1, *2
tRP
tRP
*1
tRP
tRP

tRP
1
1
tRP
tRP
tREFC
tREFC

tREFC
tREFC
tREFC
tREFC
tREFC
tREFC
tREFC

tREFC
tREFC
tREFC
tREFC
tREFC
*1: Assume other bank is in IDLE state. *2: Assume output is in High-Z state. *3: Assume tRRD is satisfied. *4: Assume tRAS is satisfied. *5: Assume appropriate DM masking.
DS05-11456-1E
19
MB81EDS256445
COMMAND DESCRIPTION
1. DESELECT (DESL)
When CS is High at the CK rising edge, all input signals are neglected. Internal operation such as burst cycle is held.
2. NO OPERATION (NOP)
NOP disables address and data input and internal operation such as burst cycle is held.
3. BANK ACTIVE (ACT)
ACT activates the bank selected by BA and latch the row address through A0 to A11.
4. READ (READ)
READ initiates burst read operation to an activated row address. Address inputs of A[7:0] determine starting column address and A10 determines whether Auto Precharge is used or not. Initially DQS output Low level then start toggling together with data output with respect to CL and BL. The read data output is edge-aligned with first rising edge of DQS and successive read data output are edge-aligned to the successive edge of DQS. The CK drives the rising edge of DQS and Even data, and the CK drives the falling edge of DQS and Odd data.
20
DS05-11456-1E
MB81EDS256445
Data Output Timing
CK
CK
CAS Latency
Command
READ
NOP
tAC (Min.) DQS
tDQSCK
tDQSCK
tLZ
DQ
tQH Qeven
tQH Qodd Qeven Qodd
tDQSQ tAC
tDQSQ tAC
tAC (Max.)
tDQSCK tDQSCK
DQS
tLZ
DQ
tQH Qeven tDQSQ tAC tAC tDQSQ
tQH Qodd
Read Preamble and Postamble @CL = 3
CK CK CL = 3
Command
READ
NOP
DQS tRPRE DQ Q0 Q1 Q2 Q3 Q4 Q5 Q6 tRPST Q7
DS05-11456-1E
21
MB81EDS256445
5. READ with Auto Precharge (READA)
READA commands can be issued by READ command with AP (A10) = H. Auto precharge is a feature which precharge the activated bank after the completion of burst read operation. The tRAS is defined from between ACTIVE (ACT) command to the internal precharge which starts after BL/2 from READA command. READ with Auto precharge operation should not be interrupted by subsequent READ, READA, WRITE, WRITEA commands. Next ACTIVE (ACT) command can be issued after BL/2 + tRP after READA command.
22
DS05-11456-1E
MB81EDS256445
6. WRITE (WRIT)
WRIT initiates burst write operation to an active row address. Address inputs of A[7:0] determine starting column address and AP(A10) determines whether Auto Precharge is used or not. DQS input must be provided in order to latch the input data. DQS must be brought to Low to satisfy the specified time duration of the Write Preamble Setup Time to CK (tWPRES). Input data window must be guaranteed with specified minimum setup and hold time against edge of DQS input (tDS, tDH). The input data appearing on DQ is written into memory cell array subject to the DM input logic level appearing coincident with the input data. If a given signal on DM is registered Low, the corresponding data will be written into the cell array. And if a given signal on DM is registered High, the corresponding data will be masked and write will not be executed to that byte. After data input with respect to BL is completed, DQS must be kept low for the specified minimum value of Write Postamble Time (tWPST). Data Input Timing
CK
CK
Command
WRIT
NOP
tDQSS (Min.) DQS
tDQSS
tDQSH
tDQSL
tDSS DQ Qeven tDS DM tDS tDH tDS tDH tDS tDH tDH Qodd tDS tDH Mask tDS tDH
tDSH Qodd tDS tDH
tDSS
tDS
tDH
tDQSS (Max.) DQS
tDQSS
tDQSH
tDQSL
tDSS DQ Qeven tDS DM tDS tDH tDS tDH tDS tDH Qodd tDS tDH
tDSH Mask tDS tDH Qodd tDS tDH
tDSS
tDH
tDS
tDH
DS05-11456-1E
23
MB81EDS256445
Write Preamble and Postamble
CK CK
Command WRITE
tWPRES DQS tWPRE DQ Q0 Q1 Q2 Q3 Q4 Q5
NOP
tWPST Q6 Q7
7. WRITE with Auto Precharge (WRITA)
WRITA commands can be issued by WRIT command with AP (A10) = H. Auto precharge is a feature which precharge the activated bank after the completion of burst write operation. The tRAS is defined from between ACTIVE (ACT) command to the internal precharge which starts after 1+ BL/2 + tWR from WRITA command. WRIT with Auto precharge operation should not be interrupted by subsequent READ, READA, WRIT, WRITA commands. Next ACTIVE (ACT) command can be issued after 1+ BL/2 + tDAL after WRITA command.
8. BURST TERMINATE (BST)
BST terminates the burst read or write operation. When a burst read is terminated by BST command, the data output will be in High-Z after CAS latency from the BST command. When a burst write is terminated by BST command, the data input after 1 clock from BST command will be masked. Terminate read by BST @CL=3
CK CL = 3 Command NOP READ BST CL = 3 NOP
DQ (output)
Q0
Q1
Terminate write by BST
CK 1 clock Command NOP WRIT BST NOP Masked by BST DQ (input) D0 D1 D2 D3
24
DS05-11456-1E
MB81EDS256445
9. PRECHARGE SINGLE BANK (PRE)
PRECHARGE SINGLE BANK (PRE) command starts precharge operation for a bank selected by BA. A selected bank will be in IDLE state after specified time duration of tRP from PRE command. A10 determines whether one or all banks are precharged. If AP(A10) = L, a bank to be selected by BA is precharged.
10. PRECHARGE ALL BANK (PALL)
PRECHARGE ALL BANKS (PALL) command starts precharge operation for all banks. All banks will be in IDLE state after specified time duration of tRP from PALL command. A10 determines whether one or all banks are precharged. If AP(A10) = H, all banks are precharged and BA input is a "don't care".
11. AUTO REFRESH (REF)
AUTO REFRESH (REF) command starts internal refresh operation which uses the internal refresh address counter. All banks must be precharged prior to the Auto-refresh command. Data retention capability depends on the Junction Temperature (Tj). Total 4,096 AUTO REFRESH (REF) commands must be asserted within the following refresh period of tREF. Tj Max ( C) + 105 + 125 tREF (ms) 16 4
12. SELF-REFRESH ENTRY (SELF)
SELF REFRESH ENTRY (SELF) commands can be issued by AUTO REFRESH (REF) command in conjunction with CKE = Low after last read data has been appeared on DQ. During Self Refresh mode, stored data can be retained without external clocking and all inputs except for CKE will be "don't care". Self refresh mode can be used when Tj is less than + 85C. Auto Refresh must be issued to retain data when Tj is greater than + 85 C.
13. SELF-REFRESH EXIT (SELFX)
To exit self-refresh mode, apply minimum tIS after CKE brought High, and then the NO OPERATION command (NOP) or the DESELECT command (DESL) should be asserted within one tREFC period. CKE should be held High within one tREFC period after tIS. Refer to the "(15) Self Refresh Entry and Exit" in "TIMING DIAGRAMS" for the detail. It is recommended to assert an Auto-refresh command just after the tREFC period to avoid the violation of refresh period.
14. MODE REGISTER SET (MRS)
MODE REGISTER SET (MRS) commands to program the mode registers. Once a mode register is programmed, the contents of the register will be held until re-programmed by another MRS command. MRS command should only be issued on conditions that all DQs are in High-Z and all banks are in IDLE state. The contents of the mode registers is undefined after the power-up and Deep Power Down Exit. Therefore MRS must be issued to set each content of mode registers after initialization. Refer to the "Power Up Initialization" in " FUNCTIONAL DESCRIPTION".
15. POWER DOWN ENTRY (PD)
POWER DOWN ENTRY (PD) commands to drive the device in Power Down mode and maintains low power state as long as CKE is kept Low. During Power Down state, all inputs signals are "don't care" except for CKE. Power Down mode must be entered on condition that all DQs are in High-Z.
16. POWER DOWN EXIT (PDX)
POWER DOWN EXIT (PDX) commands to resume the device from Power Down mode. Any commands can be detected 1 clock after PDX commands.
DS05-11456-1E
25
MB81EDS256445
17. DEEP POWER DOWN ENTRY (DPD)
DEEP POWER DOWN ENTRY (DPD) commands to drive the device in Deep Power Down mode which is the lowest power consumption but all stored data and the contents of mode registers will be lost. During Deep Power Down state, all inputs signals except for CKE are "don't care" and all DQs and DQS will be in High-Z. Deep Power Down mode must be entered on conditions that all DQs are in High-Z and all banks are in IDLE state.
18. DEEP POWER DOWN EXIT (DPDX)
DEEP POWER DOWN EXIT (DPDX) commands to resume the device from Deep Power Down mode. Power up initialization procedure must be performed after DPDX commands. Refer to the "Power Up Initialization" in " FUNCTIONAL DESCRIPTION".
26
DS05-11456-1E
MB81EDS256445
ABSOLUTE MAXIMUM RATINGS
Parameter Supply Voltage Relative to VSS Input / Output Voltage Relative to VSS Short Circuit Output Current Power Dissipation Storage Temperature Symbol VDD,VDDQ VIN, VOUT IOUT PD TSTG Rating -0.5 to +2.3 -0.5 to +2.3 50 1.0 -55 to +125 Unit V V mA W C
WARNING: Semiconductor devices can be permanently damaged by application of stress (voltage, current, temperature, etc.) in excess of absolute maximum ratings. Do not exceed these ratings.
RECOMMENDED OPERATING CONDITIONS
Parameter Supply Voltage*1 DC Input High Voltage*2 AC Input High Voltage*2 DC Input Low Voltage
*3
Symbol VDD, VDDQ VSS, VSSQ VIH (DC) VIH (AC) VIL (DC) VIL (AC) Tj
Min. 1.7 0 VDDQ x 0.7 VDDQ x 0.8 -0.3 -0.3 -10
Typ. 1.8 0
Max. 1.95 0 VDDQ + 0.3 VDDQ + 0.3 VDDQ x 0.3 VDDQ x 0.2 +125
Unit V V V V V V C
AC Input Low Voltage*3 Junction Temperature *1: VDDQ must be less than or equal to VDD.
*2: Maximum DC voltage on input or I/O pins is VDDQ + 0.3 V. During voltage transitions, inputs may positive overshoot to VDDQ + 1.0V for periods of up to 3 ns. *3: Minimum DC voltage on input or I/O pins is -0.3 V. During voltage transitions, inputs may negative overshoot to VSSQ - 1.0V for periods of up to 3 ns. WARNING: The recommended operating conditions are required in order to ensure the normal operation of the semiconductor device. All of the device's electrical characteristics are warranted when the device is operated within these ranges. Always use semiconductor devices within their recommended operating condition ranges. Operation outside these ranges may adversely affect reliability and could result in device failure. No warranty is made with respect to uses, operating conditions, or combinations not represented on the data sheet. Users considering application outside the listed conditions are advised to contact their representatives beforehand.
CAPACITANCE
Parameter Input Capacitance, Except for DM Input Capacitance for DM I/O Capacitance Symbol CIN1 CIN2 CI/O Min. 3 5 5 Typ. (Ta = + 25 C, f = 1 MHz) Max. Unit 5 7 7 pF pF pF
DS05-11456-1E
27
MB81EDS256445
ELECTRICAL CHARACTERISTICS
1. DC Characteristics
Parameter Symbol (Under recommended operating conditions unless otherwise noted) Value Condition Unit Min. Max. VDDQ - 0.2 -5 -5 V
Output High Voltage
VOH(DC) IOH = -0.1 mA
Output Low Voltage Input Leakage Current Output Leakage Current Operating One Bank Active-Precharge Current
VOL(DC)
IOL = 0.1 mA 0 V VIN VDDQ, All other pins not under test = 0 V 0 V VIN VDDQ, Data out disabled tRC = tRC min, tCK = tCK min, CKE = VIH, CS = VIH addresses inputs are SWITCHING; data bus inputs are STABLE All banks idle, CKE = VIL, CS = VIH, tCK = tCK min, address and control inputs are SWITCHING; data bus inputs are STABLE Tj + 105 C
0.2
V
ILI
5
A A
ILO
5
IDD0
65
mA
3 mA
IDD2P Precharge Standby Current
Tj + 125 C
5
IDD2N
All banks idle, CKE = VIH, CS = VIH, tCK = tCK min, address and control inputs are SWITCHING; data bus inputs are STABLE One bank active, BL = 4, Tj + 105 C tCK = tCK min, Output pin open, Gapless data, address inputs are SWITCHING; 50% data change each burst transfer Tj + 125 C
15
mA
300 mA
Operating Burst Read Current
IDD4R
280
Operating Burst Write Current
IDD4W
Tj + 105 C One bank active, BL = 4, tCK = tCK min, Gapless data, address inputs are SWITCHING; 50% data change each burst transfer Tj + 125 C tRC = tRFC min, tCK = tCK min, CKE = VIH, address and control inputs are SWITCHING; data bus inputs are STABLE
330 mA
305
Auto Refresh Current
IDD5
120
mA
(Continued)
28
DS05-11456-1E
MB81EDS256445
(Continued) Parameter Symbol Condition CKE = VIL, CS = VIL, address and control inputs are STABLE; data bus inputs are STABLE address and control inputs are STABLE; data bus inputs are STABLE Value Min. Max. 4 Unit
Self Refresh Current
IDD6
mA
Deep Power Down Current
IDD8
20
A
Notes: * All voltages are referenced to VSS. * After power on, initialization following power-up timing is required. DC characteristics are guaranteed after the initialization. * IDD depends on the output termination or load condition, clock cycle rate, signal clocking rate. The specified values are obtained with the output open condition.
DS05-11456-1E
29
MB81EDS256445
2. AC Characteristics
Parameter (Under recommended operating conditions unless otherwise noted)*1, *2 Value Symbol Unit Min. Max. tAC tDQSCK tCH tCL
4
DQ Output Access Time from CK/CK (tCK = tCK min)*3, *4, *7 DQS Output Access Time from CK/CK *3, *4 Clock High Level Width *3 Clock Low Level Width *
3
2 2 2 2 0.45 15 7.4 4.6 5 0.4 0.5 0.4 0.5 0.35 0.9 0.9 0.6 0 tDC - 0.5 0.75 0.35 0.35 0.2 0.2 2 0 0.25 0.4 0.5 0.9 0.4
6 6 0.55
ns ns ns ns tCK
Delay between CK and CK *
tDC CL = 2 CL = 3 CL = 4 Tj + 105 C Tj + 125 C Tj + 105 C Tj + 125 C Tj + 105 C Tj + 125 C tDS tDH tDIPW tIS tIH tIPW tLZ tHZ tDQSQ
3, 4 3
Clock Cycle Time
tCK
ns
DQ and DM Input Setup Time DQ and DM Input Hold Time DQ and DM Input Pulse Width Address and Control Input Setup Time *3 Address and Control Input Hold Time * DQ Low-Z Time from CK/CK *3, *5 DQ High-Z Time from CK/CK *3, *5, *6 DQS to DQ Skew *
4
6 0.4 1.25 0.6 1.1 1.1 0.6
ns ns ns tCK ns ns tCK ns ns ns ns tCK tCK tCK tCK tCK tCK ns tCK tCK tCK tCK (Continued)
Address and Control Input Pulse Width
DQ Output Hold Time from DQS * * DQS Input High Level Width DQS Input Low Level Width
tQH tDQSS tDQSH tDQSL tDSS tDSH tMRD tWPRES tWPRE tWPST CL = 2 CL = 3, 4 tRPRE tRPST
WRIT Command to 1st DQS Latching Transition
DQS Falling Edge to CK Setup Time DQS Falling Edge Hold Time from CK MRS Command Period Write Preamble Setup Time Write Preamble Time Write Postamble Time Read Preamble Time Read Postamble Time
30
DS05-11456-1E
MB81EDS256445
(Continued) Parameter ACT to PRE, PALL Command Period *7 ACT to ACT Command Period (Same Bank) *7 REF to ACT, REF Command Period ACT to READ or WRIT Command Period Precharge Period *7 ACT to ACT Command Period (Other Bank) Write Recovery Time CL = 2 Data Input to ACT, REF Command Period Internal Write to READ Command Period Average Refresh Period *8 Average Periodic Refresh Interval Transition Time *9 Tj + 105C Tj + 125C Tj + 105C Tj + 125C CL = 3 CL = 4 tWTR tREFI tREF tT tDAL (Under recommended operating conditions unless otherwise noted)*1, *2 Value Symbol Unit Min. Max. tRAS tRC tREFC tRCD tRP tRRD tWR 37 59.2 100 20 18 9.2 12 1 CLK + tRP 2 CLK + tRP 3 CLK + tRP 9.2 3.9 0.97 16 4 1 ns s ms ns ns 8000 ns ns ns ns ns ns ns
* 1: AC characteristics are measured after the Power up initialization procedure. * 2: VDD x 0.5 is the reference level for 1.8 V I/O for measuring timing of input/output signals. * 3: If input signal transition time (tT) is longer than 1 ns; [(tT/2) - 0.5] ns should be added to tAC (Max), tDQSCK (Max) and tHZ (max) spec values, [(tT/2) - 0.5] ns should be subtracted from tLZ (Min) and tQH (Min) spec values, and (tT - 1.0) ns should be added to tCH (Min), tCL (Min), tIS (Min), tIH (Min), tDS (Min) and tDH (Min) spec values. * 4: The data valid window is defined as tQH - tDQSQ. The data valid window depends on tDC which is defined between rising edge of CK and rising edge of CK. The data valid window is guaranteed when tDC is satisfied. * 5: tAC, tDQSCK, tLZ and tHZ, are measured under output load circuit shown in " 3. Measurement Condition of AC Characteristics" in " ELECRTRICAL CHARACTERISTICS" and Driver Strength (DS) = Normal, Pre Driver Strength (PDS) = Fast are assumed. * 6: Specified where output buffer is no longer driven. * 7: The sum of actual clock count of tRAS and tRP must be equal or greater than specified minimum tRC. * 8: This value is for reference only. * 9: Transition times are measured between VIH (AC) min and VIL (AC) max.
DS05-11456-1E
31
MB81EDS256445
3. Measurement Condition of AC Characteristics
VDD x 0.5 V 50 DEVICE UNDER TEST 10 pF OUT
VDD 0.1 F VSS
32
DS05-11456-1E
MB81EDS256445
TIMING DIAGRAMS
(1) Read* (Assuming CL = 4, BL = 8)
CK CK CKE CS
H
RAS
CAS
WE BA
BA BA BA BA
AP
RA
RA
Address
RA
CA
RA
DM
DQS
DQ
tRCD tRAS
Q0 Q1 Q2 Q3 Q4 Q5 Q6 Q7
tRP tRC
ACT
READ
PRE
ACT
Don't care
* : RA = Row Address, BA = Bank Address, CA = Column Address, AP = Auto Precharge
DS05-11456-1E
33
MB81EDS256445
(2) Read to Read*1 (Assuming CL = 4, BL = 8)
CK CK CKE CS
H
RAS
CAS
WE BA
0 1 0 1 1 0
AP
RA
RA
Address
RA
RA
N
N
M
M
DM
DQS
DQ
tRCD tRCD CL = 4
Q0 Q1 Q2 Q3 Q0 Q1 Q2 Q3 Q0 Q1 Q2 Q3 Q4 Q5 Q6 Q7
Q0 Q1
CL = 4 CL = 4 CL = 4
ACT Bank 0
ACT Bank 1
READ *2 Bank 0, CA = N
READ *2 Bank 1, CA = N
READ *2 Bank 1, CA = M
READ Bank 0, CA = M
Don't care
*1: RA = Row Address, BA = Bank Address, CA = Column Address, AP = Auto Precharge *2: Previous burst read can be interrupted by subsequent burst read.
34
DS05-11456-1E
MB81EDS256445
(3) Read to Precharge *1(Assuming CL = 4, BL = 8)
CK CK CKE CS
H
RAS
CAS
WE BA
BA BA BA BA BA BA
AP
RA
RA
Address
RA
CA
RA
CA
DM
DQS
DQ
tRCD CL = 4
Q0 Q1 Q2 Q3
Q0 Q1
tRCD CL = 4*2 tRAS
CL = 4
tRAS tRC ACT READ PRE*2
tRP
ACT
READ
PRE
Don't care
*1: RA = Row Address, BA = Bank Address, CA = Column Address, AP = Auto Precharge *2: Burst read operation can be terminated by PRE command. All DQ pins become High-Z after CL from PRE command.
DS05-11456-1E
35
MB81EDS256445
(7) Write with Auto-Precharge *1 (Assuming BL = 8)
CK CK
CKE CS
H
RAS
CAS
WE BA
BA BA BA
AP
Address
RA
RA
RA
CA
RA
DM
DQS
DQ
tRCD
D0 D1 D2 D3 D4 D5 D6 D7
1 + BL/2 tRAS tRC
tDAL
ACT
WRITA
Precharge start
ACT*2
Don't care
*1 : RA = Row Address, BA = Bank Address, CA = Column Address, AP = Auto Precharge *2 : Next ACT command can be issued after 1 + BL/2 + tDAL (Min) from WRITA command. tRC must be satisfied.
DS05-11456-1E
39
MB81EDS256445
(8) Read to Write *1 (Assuming CL = 4, BL = 8)
CK CK
H
CKE CS
RAS
CAS
WE BA
BA BA BA
AP
RA
Address
RA
CA
CA
DM
DQS
DQ
Q0 Q1 Q2 Q3 Q4 Q5 Q6 Q7
D0 D1 D2 D3 D4 D5 D6 D7
tRCD
CL + BL/2*2
ACT
READ
WRIT
Don't care
*1 : RA = Row Address, BA = Bank Address, CA = Column Address, AP = Auto Precharge *2 : WRIT command can be issued after CL + BL/2 after READ command.
40
DS05-11456-1E
MB81EDS256445
(9) Read to Write with BST Command *1 (Assuming CL = 4, BL = 8)
CK CK
H
CKE CS
RAS
CAS
WE BA
BA BA BA
AP
RA
Address
RA
CA
CA
DM
DQS DQ
Q0 Q1 D0 D1 D2 D3 D4 D5 D6 D7
tRCD
CL*2
ACT
READ
BST
WRIT
Don't care
*1 : RA = Row Address, BA = Bank Address, CA = Column Address, AP = Auto Precharge *2 : WRIT command can be issued after CL from burst read termination by BST command.
DS05-11456-1E
41
MB81EDS256445
(11) Write to Read with BST Command *1 (Assuming CL = 4, BL = 8)
CK CK CKE CS
H
RAS
CAS
WE BA
BA BA BA
AP
Address
RA
RA
CA
CA
DM
DQS DQ
D0 D1 Q0 Q1 Q2 Q3 Q4 Q5 Q6 Q7
Masked by BST*2
tRCD 1 + tWTR CL
ACT
WRIT
BST
READ*3
Don't care
*1 : RA = Row Address, BA = Bank Address, CA = Column Address, AP = Auto Precharge *2 : The data input after 1 clock from BST command will be masked. *3 : READ command can be issued after 1 + tWTR from burst write termination by BST command.
DS05-11456-1E
43
MB81EDS256445
(13) DM Control Write *1 (Assuming BL = 8)
CK CK
CKE CS
H
RAS
CAS
WE BA
BA BA BA BA
AP
Address
RA
RA
RA
CA
RA
DM
DQS
DQ
tRCD
D0 D1
D3 D4 D5 D6 D7
Masked *2
tRAS tRC
tWR
tRP
ACT
WRIT
PRE
ACT
Don't care
*1 : RA = Row Address, BA = Bank Address, CA = Column Address, AP = Auto Precharge *2 : When DM is registered High, the corresponding data will be masked.
DS05-11456-1E
45
MB81EDS256445
(14) Auto Refresh *1
CK CK
CKE CS
H
RAS
CAS
WE BA
BA
AP
Address
RA
RA
DM
High-Z
DQS DQ
tRP tREFC*3 tREFC*3 High-Z
PALL*2
REF
REF
ACT*4
Don't care
*1 : RA = Row Address, BA = Bank Address, AP = Auto Precharge *2 : All banks must be precharged prior to the AUTO REFRESH command (REF). *3 : Either NOP or DESL command should be asserted during tREFC period. *4 : ACT or MRS or REF command should be asserted after tREFC from REF command.
46
DS05-11456-1E
MB81EDS256445
(16) Mode Register Set*1
CK CK
CKE CS
H
RAS
CAS
WE BA
Code Code Code
BA
AP
Address
Code
Code
Code
RA
Code
Code
Code
RA
DM
High-Z
DQS DQ
High-Z
tRP
tREFC
tREFC
tMRD
tMRD
tMRD
PALL*2
REF
REF
MRS*2
MRS*2
MRS*2
ACT
Don't care
*1 : RA = Row Address, BA = Bank Address, AP = Auto Precharge *2 : MODE REGISTER SET (MRS) command must be asserted after all banks have been precharged and all DQ are in High-Z.
48
DS05-11456-1E
MB81EDS256445
(17) Power Down Entry and Exit *1
CK CK
tIS
CKE CS
RAS
CAS
WE BA
BA
AP
RA
Address
RA
DM
High-Z
DQS
High-Z
DQ
PALL
PD*2
PDX ACT*3
Don't care
*1 : RA = Row Address, BA = Bank Address, AP = Auto Precharge *2 : PD command can be issued after all DQ are in High-Z. *3 : ACT command can be issued after 1 clock from POWER DOWN EXIT (PDX) command.
DS05-11456-1E
49
MB81EDS256445
(19) Deep Power Down Exit *1
CK CK
tIS
CKE CS
RAS
CAS
WE BA
Code Code Code
BA
AP
Code
Code
Code
RA
Address
Code
Code
Code
RA
DM
High-Z
DQS
High-Z
DQ
300 s
tRP
tREFC
tREFC
tMRD
tMRD
tMRD
DPDX*2
PALL
REF
REF
MRS
EMRS
EMRS
ACT
Don't care
*1: RA = Row Address, BA = Bank Address, AP = Auto Precharge *2: Power up initialization procedure must be performed after DPDX command.
DS05-11456-1E
51
MB81EDS256445
FUJITSU MICROELECTRONICS LIMITED
Shinjuku Dai-Ichi Seimei Bldg., 7-1, Nishishinjuku 2-chome, Shinjuku-ku, Tokyo 163-0722, Japan Tel: +81-3-5322-3329 http://jp.fujitsu.com/fml/en/ For further information please contact: North and South America FUJITSU MICROELECTRONICS AMERICA, INC. 1250 E. Arques Avenue, M/S 333 Sunnyvale, CA 94085-5401, U.S.A. Tel: +1-408-737-5600 Fax: +1-408-737-5999 http://www.fma.fujitsu.com/ Europe FUJITSU MICROELECTRONICS EUROPE GmbH Pittlerstrasse 47, 63225 Langen, Germany Tel: +49-6103-690-0 Fax: +49-6103-690-122 http://emea.fujitsu.com/microelectronics/ Korea FUJITSU MICROELECTRONICS KOREA LTD. 206 Kosmo Tower Building, 1002 Daechi-Dong, Gangnam-Gu, Seoul 135-280, Republic of Korea Tel: +82-2-3484-7100 Fax: +82-2-3484-7111 http://kr.fujitsu.com/fmk/ Asia Pacific FUJITSU MICROELECTRONICS ASIA PTE. LTD. 151 Lorong Chuan, #05-08 New Tech Park 556741 Singapore Tel : +65-6281-0770 Fax : +65-6281-0220 http://www.fmal.fujitsu.com/ FUJITSU MICROELECTRONICS SHANGHAI CO., LTD. Rm. 3102, Bund Center, No.222 Yan An Road (E), Shanghai 200002, China Tel : +86-21-6146-3688 Fax : +86-21-6335-1605 http://cn.fujitsu.com/fmc/ FUJITSU MICROELECTRONICS PACIFIC ASIA LTD. 10/F., World Commerce Centre, 11 Canton Road, Tsimshatsui, Kowloon, Hong Kong Tel : +852-2377-0226 Fax : +852-2376-3269 http://cn.fujitsu.com/fmc/en/
Specifications are subject to change without notice. For further information please contact each office. All Rights Reserved. The contents of this document are subject to change without notice. Customers are advised to consult with sales representatives before ordering. The information, such as descriptions of function and application circuit examples, in this document are presented solely for the purpose of reference to show examples of operations and uses of FUJITSU MICROELECTRONICS device; FUJITSU MICROELECTRONICS does not warrant proper operation of the device with respect to use based on such information. When you develop equipment incorporating the device based on such information, you must assume any responsibility arising out of such use of the information. FUJITSU MICROELECTRONICS assumes no liability for any damages whatsoever arising out of the use of the information. Any information in this document, including descriptions of function and schematic diagrams, shall not be construed as license of the use or exercise of any intellectual property right, such as patent right or copyright, or any other right of FUJITSU MICROELECTRONICS or any third party or does FUJITSU MICROELECTRONICS warrant non-infringement of any third-party's intellectual property right or other right by using such information. FUJITSU MICROELECTRONICS assumes no liability for any infringement of the intellectual property rights or other rights of third parties which would result from the use of information contained herein. The products described in this document are designed, developed and manufactured as contemplated for general use, including without limitation, ordinary industrial use, general office use, personal use, and household use, but are not designed, developed and manufactured as contemplated (1) for use accompanying fatal risks or dangers that, unless extremely high safety is secured, could have a serious effect to the public, and could lead directly to death, personal injury, severe physical damage or other loss (i.e., nuclear reaction control in nuclear facility, aircraft flight control, air traffic control, mass transport control, medical life support system, missile launch control in weapon system), or (2) for use requiring extremely high reliability (i.e., submersible repeater and artificial satellite). Please note that FUJITSU MICROELECTRONICS will not be liable against you and/or any third party for any claims or damages arising in connection with above-mentioned uses of the products. Any semiconductor devices have an inherent chance of failure. You must protect against injury, damage or loss from such failures by incorporating safety design measures into your facility and equipment such as redundancy, fire protection, and prevention of over-current levels and other abnormal operating conditions. Exportation/release of any products described in this document may require necessary procedures in accordance with the regulations of the Foreign Exchange and Foreign Trade Control Law of Japan and/or US export control laws. The company names and brand names herein are the trademarks or registered trademarks of their respective owners. Edited: Sales Promotion Department


▲Up To Search▲   

 
Price & Availability of MB81EDS256445

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X